A. REGULATED DC POWER SUPPLY WITH SMD TECHNOLOGY                [TOC]

1. 30 Volts/1Amp Continuously Variable Regulated Power Supply :

  Voltage Range : 0-30V

  Voltage Control : Single turn coarse & fine controls

  Current : 1 Amp

  Current Control : Single turn control

  Load Regulation : 0.01% ±3mV

  Line Regulation : 0.01% ±3mV

  Ripple (0-20MHz) : 1mV rms

  Transient Recovery time : 50 µsec

  Stability : 0.1% for 8 hrs after 1/2 an hour warm up

  Meters : Individual 3 digit DPM to indicate volt & Amps : 1 Meters

  Terminals : Provided on the front panel

 # Input :

  Voltage/Frequency : 230V ±10%, 50Hz (Single Phase)

  Connection : 3 Pin, 5 Amps mounded cord

 # Protection:

  Overload & Short Circuit : Continuously preserrable by current control.

  OverLoad(Optional) : Preset able to trip for 10% 110% of Vnom

 # Environmental :

  Operating Temperature : 0-50E C

  Humidity : 90% RH at 45E C non-condensing

  Cooling : Natural Convection

Note:The Input, Protection, Environmental are common for all the below mentioned power supplies

2. 30 Volts/2Amps Continuously Variable Regulated Power Supply :

  Voltage Range : 0-30V

  Voltage Control : Single turn coarse & fine controls

  Current : 2 Amps

  Current Control : Single turn control

  Load Regulation : 0.01% ±3mV

  Line Regulation : 0.01% ±3mV

  Ripple (0-20MHz) : 1mV rms

  Transient Recovery time : 50 µsec

  Stability : 0.1% for 8 hrs after 1/2 an hour warm up

  Meters : Individual 3 digit DPM to indicate volt & Amps : 1 Meters

  Terminals : Provided on the front panel [ 10 ]

3. (0-30V, 5A) Variable Regulated output DC Power supply unit

  Voltage Range : 0-30V/5A

  Metering : individual 3 digit DPM to indicate volts & Amps

  Load Regulation : 0.01%±3mV

  Line Regulation : 0.01%±3mV

  Ripple : 1mV Rms (0-20MHz)

  Transient recovery time : 50µsec

  Input Voltage/Frequency : 230V±10%, 50Hz single phase AC

  Protection : Overload & short circuit Over voltage protection

  Operating Temperature : 0-50EC

B. DUAL REGULATED DC POWER SUPPLY WITH SMD TECHNOLOGY             [TOC]

1. Dual 30 Volts/1Amp Continuously Variable Regulated Power Supply :

  Voltage Control : Single turn coarse & fine controls

  Current : 1 Amp

  Current Control : Single turn control

  Load Regulation : 0.01% ±3mV

  Line Regulation : 0.01% ±3mV

  Ripple (0-20MHz) : 1mV rms

  Transient Recovery time : 50 µsec

  Stability : 0.1% for 8 hrs after 1/2 an hour warm up

  Meters : Individual 3 digit DPM to indicate volt & Amps : 2 Meters

  Terminals : Provided on the front panel

2. Dual 30 Volts/2Amps Continuously Variable Regulated Power Supply :

  Voltage Range : 0-30V, 0-30V

  Voltage Control : Single turn coarse & fine controls

  Current : 2 Amps

  Current Control : Single turn control

  Load Regulation : 0.01% ±3mV

  Line Regulation : 0.01% ±3mV

  Ripple (0-20MHz) : 1mV rms

  Transient Recovery time : 50 µsec

  Stability : 0.1% for 8 hrs after 1/2 an hour warm up

  Meters : Individual 3 digit DPM to indicate volt & Amps : 2 Meters

  Terminals : Provided on the front panel [ 11 ]

C. FIXED DC POWER SUPPLY WITH SMD TECHNOLOGY                                [TOC]

1. 5Volt/1 Amp Fixed DC Power Supply :

  Voltage Range : 5V

  Voltage Control : Single turn lockable control for the output

  Current : 1 Amp

  Current Control : Internally preset

  Load Regulation : 0.1%

  Line Regulation : 0.1%

  Ripple (0-20MHz) : 1mV rms

  Transient Recovery time : 50 µsec

  Stability : 0.1% for 8 hrs after 1/2 an hour warm up

  Meter : One

  Terminals : Provided on the front panel

2. 5Volt/5Amps Fixed DC Power Supply :

  Voltage Range : 5V

  Voltage Control : Single turn lockable control for the output

  Current : 5 Amps

  Current Control : Internally preset

  Load Regulation : 0.1%

  Line Regulation : 0.1%

  Ripple (0-20MHz) : 1mV rms

  Transient Recovery time : 50 µsec

  Stability : 0.1% for 8 hrs after 1/2 an hour warm up

  Meter : One

  Terminals : Provided on the front panel

3. 5Volt/10 Amps Fixed DC Power Supply :

  Voltage Range : 5V

  Voltage Control : Single turn lockable control for the output

  Current : 10 Amps

  Current Control : Internally preset

  Load Regulation : 0.1%

  Line Regulation : 0.1%

  Ripple (0-20MHz) : 1mV rms

  Transient Recovery time : 50 µsec

  Stability : 0.1% for 8 hrs after 1/2 an hour warm up

  Meter : One

  Terminals : Provided on the front panel [ 12 ]

4. ±15Volt/1Amp Fixed DC Power Supply :

  Voltage Range : ±15V

  Voltage Control : Single turn lockable control for the output

  Current : 1 Amp

  Current Control : Internally preset

  Load Regulation : 0.1%

  Line Regulation : 0.1%

  Ripple (0-20MHz) : 1mV rms

  Transient Recovery time : 50 µsec

  Stability : 0.1% for 8 hrs after 1/2 an hour warm up

  Meters : One

  Terminals : Provided on the front panel

5. ±15Volt/2Amps Fixed DC Power Supply :

  Voltage Range : ±15V

  Voltage Control : Single turn lockable control for the output

  Current : 2 Amps

  Current Control : Internally preset

  Load Regulation : 0.1%

  Line Regulation : 0.1%

  Ripple (0-20MHz) : 1mV rms

  Transient Recovery time : 50 µsec

  Stability : 0.1% for 8 hrs after 1/2 an hour warm up

  Meters : One

  Terminals : Provided on the front panel

6. ±15Volts/3Amps Fixed DC Power Supply :

  Voltage Range : ±15V

  Voltage Control : Single turn lockable control for the output

  Current : 3 Amps

  Current Control : Internally preset

  Load Regulation : 0.1%

  Line Regulation : 0.1%

  Ripple (0-20MHz) : 1mV rms

  Transient Recovery time : 50 µsec

  Stability : 0.1% for 8 hrs after 1/2 an hour warm up

  Meters : One

  Terminals : Provided on the front panel[ 13 ]

D. MULTI OUTPUT REGULATED POWER SUPPLY :                                    [TOC]

1. Four Output regulated power supply

Four Output : 0-30V, 2A

+12V/+15V, 0-0.5A

-12V/-15V, 0-0.5A

+5V, 0-5A

Metering : 3 digits DPM

Accuracy : ±3 counts

Regulation : Line : ±0.01%

Load : ±0.01%

Ripple & Rise : 1mV RMS Max. 20Hz-20MHz

Output Polarity : Floating with respect to ground

Transient response : 100sec to within 10mV of set output voltage

Operating Voltage : 0-50EC

Line Voltage : 230V ± 10% Overload and short circuit protection.

E. HIGH VOLTAGE DC POWER SUPPLY                                                       [TOC]

1. (0 - 300V, 1A) high Voltage DC Power Supply

  Voltage Range : 0-300V/1A

  Metering : individual 3 digit DPM to indicate volts & Amps

  Load Regulation : 0.01%±3mV

  Line Regulation : 0.01%±3mV

  Ripple : 1mV Rms (0-20MHz)

  Transient recovery time : 50µsec

  Input Voltage/Frequency : 230V±10%, 50Hz single phase AC

  Protection : Overload & short circuit Over voltage protection

  Operating Temperature : 0-50EC [ 14 ]