- 2 Annunciators provided for output indication.
- One 2Kg stepper motor.
- One 12V miniature DC motor with optical encoder for feed back.
- One limit switch to simulate the PLC input.
- One Buzzer to simulate the PLC output
- Traffic light Demonstration is provided
- One Solid state relay.
- One Proximity switch for metal detection.
|
 |
|
|
|
| |
DC MOTOR SPEED CONTROL
TRAINER [VPAT - 02]
|
- 12V PMDC motor,
- PWM based driver,
DC motor in PID
- Speed indicator,
- Optical Encoder with F/V converter
.
|
 |
|
|
|
|
|
TRAFFIC LIGHT CONTROL
TRANIER [VPAT - 03] |
- Traffic Light System represented with different color LED’s.
- Built in Power supply.
|
 |
|
|
|
BOTTLE FILLING
TRAINER [VPAT - 04]
|
- A stepper motor controlled Rotary mechanism,
- Suitable power supply,
- Solenoid valve to fill the Bottle,
- Process tank,
- One proximity sensor and a optical sensor.
- One Reservoir tank with FHP pump to feed the water to Process tank
- Two magnetic switches to maintain the two fixed level of water in Process tank .
|
 |
|
|
PLC RTA - BATCH PROCESS REACTOR
TRAINER [VPAT - 05] |
- A stepper motor controlled Rotary mechanism,
- Conveyor Mechanism with timer pulley arrangement.
- Suitable power supply,
- solenoid valves to fill the Process Tank and the vessel,
- Process tank with Stirrer and Heater.
- One proximity sensor to detect the vessel.
- One Reservoir tank with two FHP pumps to feed the water to two Process tanks
- Magnetic switches to maintain the two fixed level of water in Process tanks..
|
 |
|
|
PLC RTA - LEVEL CONTROL
TRAINER [VPAT - 06] |
- A Process Tank
- Two magnetic switches to maintain the two fixed level of water in Process tank .
- A Reservoir Tank fitted with pump To feed the water to Process tank.
- A Solenoid Valve fitted at the outlet of Process Tank.
- Built in power supply with relay driving mechanism
|
 |
|
|
PLC RTA - MATERIAL HANDLING
TRAINER [VPAT - 07]
|
- One 7Kg stepper motor for arm movement.
- One stepper motor (7Kg) for conveyor control.
- Conveyor Mechanism with timer pulley arrangement.
- One proximity sensor to detect the presence of material.
- Two limit switches to control Arm movement
- A Electromagnet in the arm to pick up the metal object.
|
 |
|
|
PLC RTA - PNEUMATIC STAMPING
TRAINER
[VPAT - 08]
|
- Two inductive/capacitive sensors to sense the object presence.
- A double acting pneumatic cylinder fixed horizontally in the
loading unit to push the job from the loading unit to the stamping table.
- A sliding conveyor with roller arrangement to slide the job to be stamped.
- A mechanical support to hold the job for stamping/stamping.
- A double acting cylinder fixed on a Stamping Holder to stamp the
job
- One pneumatic cylinder fixed horizontally to push the finished jobs
from the stamping unit to the conveyor
- A sliding conveyor with roller arrangement to slide the finished jobs to the storage bin.
- Built-in power supply.
|
 |
|
|
PLC RTA - PNEUMATIC BATTERY TESTING
TRAINER
[VPAT - 09] |
- A transparent battery reservoir compartment of capacity 10 Nos.
- A double acting cylinder fixed horizontally to push the battery & load the battery to the testing
station..
- A pneumatic arm plunger to pick up the battery to the testing station
- Magnetic reed switches to sense the position of arm.
- One Inductive/ capacitive sensors to check the battery as a conductive/non conductive
material at testing station.
- Two separate battery holder of capacity 5 nos to store the tested batteries
- Two pair of test electrodes provided to check the holded battery voltage.
- Built-in power supply.
|
 |
|
|
PLC RTA - AC MOTOR SPEED CONTROL
TRAINER
[VPAT - 10] |
- One 230V AC Motor of 2000 RPM.
- One Optical encoder to sense the speed of the motor
- Thyristor based power driver to drive the AC Motor
- Speed indicator
|
 |
|
|
PLC RTA - TEMPERATURE CONTROLLER
TRAINER
[VPAT - 11] |
|
- A Process tank with heater
- One AD-590 temperature sensor with the signal conditioner (Output: 0-10Volt.)
- Thyristor based power driver to provide 0-230 Volt pulsating DC to the
heater coil.
- Input: 0-10Volt,
- Output: 0-220Volt
- One Temperature indicator to display the temperature of water bath.
|
 |
|
|
|
PLC RTA - HYDRAULIC LINEAR ACTUATION
TRAINER
[VPAT - 12] |
- A Reservoir tank with oil of 25 Lts-35 Lts with level indicator.
- One AC motor with Hydraulic gear pump,to pump the oil with high pressure.
- One manifold valve with DC solenoid valve for directional control.
- A hydraulic cylinder with two ports.
- A DC solenoid valve for manual operations
- One check valve for non-returning of oil
- One Relief valve for releasing extra oil pressure
- 2 flow control valves.
|
 |
|
| |
| PLC RTA - RELAY TESTING
TRAINER [VPAT - 13] |
- 4 nos of power relays provided.
- Coil supply : 24VDC.
- Contacts rating : 230AC/6Amps.
- LEDs to indicate the ON/OFF status.
|
 |
|
|
|
PLC RTA - DIRECT - ON - LINE STARTER
TRAINER
[VPAT - 14] |
- Voltage transformers with Ground isolation
- A current Transformer of 5 Amps to sense the load current.
- One 0.5HP AC Induction Motor for loading
|
 |
|
|
PLC RTA - STAR - DELTA STATER
TRAINER
[VPAT - 15] |
- Voltage transformers with Ground isolation
- A current Transformer of 5 Amps to sense the load current.
- One 0.5HP AC Induction Motor for loading.
- 3Nos. of Relay to actuate the 3 phase motor individually
|
 |
|
| |
PLC RTA - CAR PARKING MONITOR
TRAINER
[VPAT - 16] |
|
|
- 3 color LEDs to indicate the status of parking slots.
- 6 sensors provided to sense the presence of car
- One stepper motor driver mechanism to actuate the Toll gate of parking area
|
. |
|
|
PLC RTA - LIFT CONTROL
TRAINER
[VPAT - 20]
|
- A lead screw mechanism.
- A 7Kg stepper motor gear mechanism
- A MOSFET based stepper motor driver.
- Demand Req. switch for 3 floors
- 3 LED outputs to indicate the status of the lift.
|
 |
|
| |
|
CONVEYOR
CONTROL SYSTEM [VPAT-24]
-
One
stepper motor (7Kg) is used for convey
control
-
One
proximity sensor is used to detect the
Presence of material.
-
One
timer belt is used for convey movement
|
 |